3000PRO Coating Thickness Gauge with Interchangeable Probes |
The new Check-Line 3000PRO Series coating thickness gauge is a multifunctional fully menu driven gauge for fast, professional and precise coating thickness measurement for: · paint and electroplated coatings on iron and steel
· paint and anodising coatings on non-ferrous metals and on austenitic stainless steels
The user will select one or more probes best suited for their application to connect to the 3000PRO gauge as all the probes are interchangeable and their internal calibration is stored within a small micro0chip inside the probe connector housing. This provides for quick and easy hot-swapping from one probe to any other in seconds.
Eight (6) separate probes are offered for a wide variety of applications. |
|
|
Measuring principle: |
Magnetic induction method (F-version); Eddy current method (N-version) |
Measuring range: |
3000PRO: 0 - 60.00 mils / 0 - 1500 µm |
Tolerance: |
± (0.7 µm/0.04 mils + 1% of reading) |
Resolution: |
Refer to RESOLUTION TABLE, above |
Display: |
4-digit display (digit height 10 mm/0.4”) and 32 alphanumerical characters; switchable backlight |
Minimum measurement area: |
5 mm x 5mm/0.2” x 0.2” |
Minimum curvature radius: |
convex 2mm/0.08”; concave 5mm/0.2” |
Minimum substrate thickness: |
0.2mm/8 mils (for F-versions); 50 µm/2 mils (for N-versions) |
Calibration methods: |
- Factory calibration: no calibration required for standard applications - Zeroing (1-point calibration): measurements on small geometries - Zeroing and foil calibration (2-point calibration): increased measuring accuracy - Two-foil calibration: especially for rough, sand-blasted surfaces - CTC: calibration on coated object if zeroing is not possible - Zero offset: addition/subtraction of a constant value to/from the reading |
Limit values: |
Selectable; optical and acoustic signal if limit value is exceeded |
Scan mode: |
For continuous measurements; for the quick recognition of coating thickness variations; with permanent display of minimum and maximum reading |
Statistics: |
Single-value statistics: n, avarage x, s, kvar, min, max, cp, cpk from max. 10,000 readings Block-value statistics: n, avarage x , avarage s, avarage kvar , min, max, cp, cpk; block size 3 to 100 readings |
Data memory: |
10,000 readings in max. 500 selectable files; alphanumerical file names; stored readings and statistical values individually recallable |
Interfaces: |
Infrared and serial RS232 interface |
Language: |
Operator prompting and documentation in German, English, French (optional other languages) |
Operating temperature: |
0 °C to 50 °C/32 °F to 122 °F (storage temperature - 20 °C to +60 °C/-4 °F to 140 °F) |
Surface temperature: |
5° F - 140° F / -15° C - 60° C (standard) 5° - 302° F / 15° - 150° C (w/optional footer) |
Power supply: |
2 x round cell (AA) 1.5 V up to 60 hours of operating time |
Housing/keypad: |
Protection class IP52 (protection against dust and dripping water) |
Dimensions: |
Gauge: 140 mm x 62 mm x 30mm/5.6” x 2.5” x 1.2” (HxWxD) Probe: dia. 14 mm x 83mm/dia. 0.56” x 3.3” |
Weight: |
approx. 200 g/7 oz (gauge including batteries and probe) |
Standards: |
DIN EN ISO, ASTM, BS |
Warranty |
1 Year |
Calibration Certificate |
Included |