你好!欢迎光临北京中仪友信科技有限公司!已注册[登录] 新用户[免费注册]
免费销售电话
就是要仪器网>>产品中心>>物理性质检测仪器>>涂装设备>>炉温数据记录仪>>

TY10高速数据采集系统ZX21

TY10

高速数据采集系统

ZX21
高速数据采集系统
订 货 号:zy413732 品    牌:美国Astro-Med,Inc 产    地:美国 市 场 价: 折 扣 价: 发货周期:现货或5天内
加入购物车 支付宝购买 询价留言
分享到:分享到搜狐微博 分享给QQ好友 分享到爱分享 分享到白社会 分享到开心网 分享到人人网 分享到豆瓣 分享仪器
产品描述技术方案相关仪器最新上架商品咨询使用评价
产品描述:

Astro-Med Recorders Maintain their Position as the Easiest to Use Data Acquisition Systems on the Market.
 
Stop fumbling with those awkward buttons or knobs and complicated configurations! The TMX features an exclusive full-color 17” advanced touch screen technology, as well as pre-defined set up options, eliminating the need for training. With the TMX, you will be an expert in no time!
 
Don’t miss a single glitch! With a 800 kHz Sample Rate per channel and 100 kHz bandwidth, the TMX enables you to detect the slightest anomalies quickly and easily. With up to 96 channels and a 1 TByte hard drive dedicated solely to data capture, all your signals can be monitored for months on end without interruption and captured in one single file. Embedded scope capture and intelligent triggering allow you to see details of your data, preserving hard drive space and minimizing archive time. In addition, the TMX LookBack™ feature allows you to review data during ongoing capture!
 
No more downtime waiting to review those large data files! The TMX has been optimized for quick data review and archive. The QuickLook™ feature allows the review of several GB of data on the touch screen in seconds. The advanced architecture of the TMX allows blazing archive speeds to transfer data to a USB flash drive or network drive. You can also take your removable data capture drive to your personal computer for immediate review on the optional AstroDock docking station. You don’t have to wait for your data to analyze it.
 
Advanced derived channel technology in the TMX enables real-time advanced mathematics on the fly with no processing latency. From simple addition, subtraction, multiplication and division to complex polynomial algorithms, the TMX synchronizes derived channels with your analog signals while capturing data! Save multiple channels of derived data without taking up file space. The TMX saves your equation and upon review instantly recalculates derived channels, time synchronized with your analog signals.
 
With the TMX, there’s no need to purchase numerous components or struggle with unwieldy set-ups. The modular, field-configurable TMX accepts all of your inputs, including analog, video, audio, IRIG, MIL-1553 and more, all in one system! Worried about data correlation errors with different inputs? Don’t be. All inputs are fully synchronized, eliminating latency.
 
Leading the way with the most cutting edge test and measurement technology, the TMX has proven to maximize efficiency and productivity so you can get to the solution faster than ever. That’s High-Speed Data Acquisition.
 


技术参数:

TMX MAINFRAME
MAINFRAME CHASSIS
Maximum Analog Modules
3 (6 with optional expansion unit)
Maximum Analog Waveforms 48 (96 with optional expansion unit)
Event Inputs (TTL) 16
Derived Channels Addition, Subtraction, Multiplication, Division, Exponential,
Sine, Cosine, Tangent, Square Root & Absolute Value
Pre-capture filters Low pass, high pass, band pass, band stop, RMS
Post-capture filters Low pass, high pass, band pass, band stop
User Engineering Units Yes
Calibration Semi-automated to external reference
DATA ACQUISITION RECORDING
Operational Modes
Scope, Review, Real-time (strip-chart)
Recording Method Internal removable 1 Tbyte SATA disk drive
Total Capacity Over 400 billion samples
Maximum Record Up to the drive capacity
Data Stored Raw (unfiltered) data saved to the drive
Time Stamp Time and date automatically saved with data
Trigger Types Edge, window, slew, event, manual & external
Trigger Point Amount of pre and post trigger is user adjustable
Auto Re-Arm Automatic stacking of captures
File Information Information on units, measurement range and sample rate saved with data
COLOR DISPLAY
Type
Active matrix color LCD (TFT)
Viewing Area 17 inch / 43.18 cm (diagonal)
Resolution 1280 x 1024
Touch Full screen, resistive
COMPLIANCE / ENVIRONMENTAL
Safety
EN 61010-1, 2nd Edition (2001) , UL 61010-1:2004, 2nd Edition
CAN/CSA C22.2 No. 61010-1:2004 2nd Edition
EMC FCC Part 15, Subpart B, Class A; EN 61326-1 Class A
Power Harmonics IEC 1000-3-2
Operating Temp 40 to 105 °F (5 to 40 °C)
Operating Humidity 10 % to 90 % non condensing
Shock MIL-STD-810F Method 516.5, Procedure I
Vibration MIL-STD-810F Method 514.5, Procedure I
POWER
AC Input Voltage Range
102 to 264 VAC
AC Input Voltage Frequency Range 47 Hz to 63 Hz
Power Consumption 300 W maximum
DC Input Voltage 24 VDC (Regulated +/- 0.5V) @ 11A
DC Input Power 264 W maximum
PHYSICAL
Enclosure
Aluminum, with armored end caps
Dimensions 14.5” ( 36.8 cm) H x 19” ( 48.3 cm) W x 7.5” (19.1 cm) D (without handle)
Weight (including 3 modules) 37 lbs (15.28 kg) varies based on installed modules
INTERFACE
Ethernet
1000BaseT
VGA For displaying data on an external monitor
USB 2.0 (8 ports per unit) For external peripherals and file export
Expansion Port For connection of optional TMX-E expansion chassis
   
TMX - INPUT MODULE SPECIFICATIONS
UNIV-6 Universal Isolated Voltage Module with DC Bridge
UNIV-6 General Specifications
Channels (per module)
6
Maximum Sample Rate (per channel) 800 kHz (400 kHz with optional TMX-E expansion chassis)
Maximum Bandwidth (Single Ended Input) 100 kHz (-3db) (400 V, 200 V and 50 V attenuators)
90 kHz (-3db) (10 V and 1 V attenuators)
Maximum Bandwidth (Differential Input) 50 kHz (all attenuators)
Isolation 250 Vrms or DC, Cat II
(channel to chassis, channel to channel)
A/D Resolution 16 bit (separate A/D per channel)
Anti-Aliasing Filter 4 pole Bessel
Accuracy (25°C) ± 0.07 % of attenuator
Frequency Counter 1 (first channel of each UNIV-6 module)
Frequency Counter Modes Frequency to Voltage (time and cycle based), Duty Cycle ,
Pulse Width and Period Detector
Frequency Counter Range 2 Hz - 40 kHz (48 Hz - 100 kHz for cycle based frequency counter)
Frequency Counter Accuracy ± 0.07 % of measurement + .002 Hz
Minimum Counter Input Amplitude 25 % of span for frequency and pulse counters
90 % of span for all other counter modes
Pulse Counter Range 64000000 maximum (16 bit display resolution)
Pulse Width Range 10 uS - 40000 uS
Pulse Width Accuracy 0.7 uS + .00167 % of span
Period Width Range 5 uS - 90000 uS (11 Hz - 200 kHz)
Period Width Accuracy 0.02 % of measurement + 0.00167 % of span with a maximum of 1.0 uS
Duty Cycle Range 15 hz - 10 kHz range with 20 % - 80 % duty cycles
Duty Cycle Accuracy 0.5 % of measurement
Cold Start Drift < 0.1 % of attenuator (60 min.)
UNIV-6 Single Ended Voltage Input
Input Type
Single Ended, AC/DC coupled
Isolated Input Connector Guarded banana jacks (red/black)
Max Rated Input 250 Vrms or DC, Cat II
Max Transient Input ± 800 V (not to exceed 250 Vrms)
Specified Ranges 200 mVFS to 800 VFS
Attenuators 1 V, 10 V, 50 V, 200 V, 400 V
Minimum Input Impedance 1 MΩ
Intrinsic Noise (pk-pk) < 0.17 % of attenuator + 0.07 % of span (1 V attenuator)
< 0.08 % of attenuator + 0.08 % of span (10 V through 40 V attenuators)
IMR @ 60 Hz > -75 db
UNIV-6 Differential Voltage Input / Bridge Measurements
Input Type
Differential, DC coupled
Isolated Input Connector Screw terminal header (removable)
Max Rated Input ± 3 VDC
Max Transient Input ± 20 VDC
Specified Ranges 5 mVFS to 2 VFS
Attenuators 50 mV , 500 mV, 1000 mV
Minimum Input Impedance 300 kΩ (150 kΩ balanced to isolated common)
Intrinsic Noise (pk-pk) < 0.14% of attenuator + 0.08% of span (50 mV attenuator)
< 0.08 % of attenuator + 0.09 % of span (500 mV & 1000 mV attenuators)
CMR @ 60 Hz > -85 db
Excitation DC Adjustable 0.1 to 10V @ 30 mA maximum
NIDV-16 Non-isolated Differential Voltage Module
Channels (per module)
16
Maximum Sample Rate (per channel) 200 kHz (100 kHz with optional expansion chassis)
Maximum Bandwidth 40 kHz
Input Type Differential, non-isolated DC coupled
Differential Input Connector 25-pin D-sub male connectors (8 channels per connector)
A/D Resolution 16 bit (separate A/D per channel)
Anti-Aliasing Filter 4 pole Bessel
Maximum Rated Input ± 50 VDC (35 Vrms)
Maximum Transient Input ± 60 V Peak
Specified Ranges 80 mVFS to 100 VFS (with zero offset)
Attenuators 200 mV, 400 mV, 800 mV, 2 V, 4 V, 5 V, 10 V, 25 V, 50 V
Minimum Input Impedance > 500 kΩ (250 kΩ balanced to signal common)
Accuracy (25°C) ± 0.07 % of attenuator (800 mV, 2, 4, 5, 10, 25 & 50 V attenuators)
± 0.1 % of attenuator (400 mV attenuator)
± 0.15 % of attenuator (200 mV attenuator)
Intrinsic Noise (pk-pk) < 0.1% of attenuator + 4 mV
CMR @ 60 Hz > -60 db
Auxiliary Power Output 12V @ 200 mA (using pin 25 on both connectors)
Frequency Counter 2 (first and second channel of each NIDV-16 module)
Frequency Counter Modes Frequency to Voltage (time and cycle based), Pulse Counter,
Quadrature Event Counter, Duty Cycle , Pulse Width and Period Detector
Frequency Counter Range 2 Hz - 40 kHz (48 Hz - 100 kHz for cycle based frequency counter)
Frequency Counter Accuracy ± 0.05 % of measurement + .002 Hz
Minimum Counter Input Amplitude 25 % of span for frequency and pulse counters
90 % of span for all other counter modes
Pulse Counter Range 64000000 maximum (16 bit display resolution)
Pulse Width Range 40 uS - 40000 uS
Pulse Width Accuracy 1.5 uS + .00167 % of span
Period Width Range 5 uS - 90000 uS (11 Hz - 200 kHz)
Period Width Accuracy 0.2 % of measurement + .00167 % of span
Duty Cycle Range Accuracy 0.5% (Inputs in the 15 Hz - 10 kHz range with 20% - 80% duty cycles)
Duty Cycle Accuracy 0.5 % of measurement
IHVM-6 Isolated High Voltage Module
Channels (per module)
6
Maximum Sample Rate (per channel) 800 kHz (400 kHz with optional TMX-E expansion chassis)
Maximum Bandwidth
60 kHz (-3db)
Input Type Differential, DC coupled
Isolated Input Connector Guarded banana jacks (red/black)
A/D Resolution 16 bit (separate A/D per channel)
Anti-Aliasing Filter 4 pole Bessel
Max Rated Input
600 Vrms or 1000 VDC, Cat IV
Max Transient Input +/- 2000 V peak
Specified Ranges 1 VFS to 2000 VFS
Attenuators 40 V, 200 V and 1000 V
Minimum Input Impedance 4 MΩ (2 MΩ balanced to isolated common)
Accuracy (25°C) ± 0.07 % of attenuator
Intrinsic Noise (pk-pk) 40 V attenuator (< 0.11 % of attenuator + 0.08 % of span)
200 V attenuator (< 0.04 % of attenuator + 0.08 % of span)
1000 V attenuator (< 0.02 % of attenuator + 0.08 % of span)
IMR @ 60 Hz -65 db (40 V, 200 V attenuators)
-60 db (1000 V attenuator)
Frequency Counter 1 (first channel of each IHVM-6 module)
Frequency Counter Modes Frequency to Voltage (time and cycle based), Pulse Counter, Duty Cycle,
Pulse Width and Period Detector
Frequency Counter Range 2Hz - 60 kHz
Frequency Counter Accuracy ± 0.07% of measurement + .002 Hz
ITCU-12 Isolated Thermocouple Module
Channels (per module) 12
Input Type Type U miniature thermocouple (12 connectors)
Isolation 250 Vrms or DC, Cat II (channel to chassis, channel to channel)
Maximum Bandwidth 5 Hz update rate (TC sampled at 2.5 Hz)
Max Rated Input ± 10 V
A/D 24 bit Sigma Delta (separate A/D per channel)
Anti-Aliasing Filter Inherent
Resolution 0.1 °C
Thermocouple Types J, K, E, T, N, B, R, S & C
Specified Range (J) -210 to 1200 °C Accuracy (25°C) J (-200 to 0) +/- 3.0 °C (0 to 1200) +/- 1.0 °C
Specified Range (E) -200 to 1000 °C Accuracy (25°C) E (-200 to -100) +/- 2.0 °C
Specified Range (N) -200 to 1300 °C Accuracy (25°C) N (-200 to -50) +/- 1.5 °C (-50 to 1300) +/- 0.8 °C
Specified Range (R) -20 to 1768 °C Accuracy (25°C) R +/- 4.0 °C
Specified Range (K) -200 to 1372 °C Accuracy (25°C) K (-200 to 0) +/- 2.5 °C (0 to 1372) +/- 1.5 °C
Specified Range (T) -200 to 400 °C Accuracy (25°C) T (-200 to -100) +/- 3.0 °C (-100 to 400) +/- 1.0 °C
Specified Range (B) 600 to 1820 °C Accuracy (25°C) B +/- 4.5 °C
Specified Range (S) -20 to 1768 °C Accuracy (25°C) S +/- 4.0 °C
Specified Range (C) 0 to 2316 °C Accuracy (25°C) C +/- 2.5 °C
Specified Range 100 mV Accuracy (25°C) +/- 0.05 % of attenuator
Cold Junction Compensation Yes, on each channel
Compensation Error Included in above accuracy specifications
Intrinsic Noise (pk-pk, J,N) < 0.15 °C
Intrinsic Noise (pk-pk, K,E,T) < 0.10 °C
Intrinsic Noise (pk-pk, B,R,S) < 1.0 °C
Intrinsic Noise (pk-pk, C) < 0.5 °C
Intrinsic Noise (pk-pk, 100 mV) < 0.007 % of attenuator
IMR > 110 dB @ DC
Linearization NIST ITS-90
Note: specified accuracy does not include probe errors.
COMING SOON (please contact Test & Measurement Sales for additional details)
IBRM-6 Isolated Bridge Module
Channels (per module) 6
Maximum Sample Rate (per channel) 800 kHz (400 kHz with optional TMX‐E expansion chassis)
Maximum Bandwidth 50 kHz
Input Type Isolated Differential
Isolation 250 Vrms or DC, Cat II
TEDS Capability YES
IEPE-6 Isolated Piezoelectric Sensor Module
Channels (per module) 6
Maximum Sample Rate (per channel) 800 kHz (400 kHz with optional TMX‐E expansion chassis)
Maximum Bandwidth Up to 30 kHz
Input Type Isolated Differential
Isolation 250 Vrms or DC, Cat II
TEDS Capability YES
   
TMX OPTIONS
TMX-VA Video / Audio Acquisition
Analog Input Type / Connector Composite / BNC
Supported Video Formats NTSC, PAL
Synchronization with waveforms +/- 1 video frame
Maximum Capture Length NTSC: Limited to remaining data capture drive space
PAL: Limited to 2 hour data captures
Supported TMX Operating Modes Realtime
LookBack Capability No
Pre-trigger capture No
Trigger capability Manual Trigger Only
NTSC Capture Resolution 720 x 480 pixels
NTSC Capture Rates 5, 10, 20, 30 fps (frames per second)
PAL Capture Resolution 720 x 576 pixels
PAL Capture Rates 5, 25 fps (frames per second)
Multimedia Format AVI with MPEG-4 compression
Audio Resolution 16-bit
Audio Mode Mono
Audio Capture Rate 11 kHz
TMX-E Expansion Chassis (Requires TMX mainframe chassis for operation)
Maximum Analog Modules
3
Maximum Analog Waveforms 48
Enclosure Aluminum, with armored end caps
Dimensions 14.5” (36.8 cm) H x 19” (48.3 cm) W x 5.04” (12.8 cm) D (without handle)
Weight (including 3 modules) 15 lbs (6.8 kg) varies based on installed modules
Input Voltage Range 102 to 264 VAC
Frequency Range 47 Hz to 63 Hz
TMX-R Rackmount Version* (Fits standard 19" racks)
Maximum Analog Modules**
6
Maximum Analog Waveforms 96
Enclosure Aluminum, rackmountable
Dimensions 15.75” (40 cm) H x 19” (48.2 cm) W x 17.15” (43.6 cm) D (without handle)
Weight (including 6 modules) 47 lbs (21.3 kg) varies based on installed modules
Input Voltage Range 102 to 264 VAC
Frequency Range 47 Hz to 63 Hz
Ethernet 1000BaseT
VGA For displaying data on an external monitor
USB 2.0 (9 ports: 8 in back and 1 in front of unit ) For external peripherals and file export
* The DATA ACQUISITION RECORDING and COLOR DISPLAY sections above also apply to the TMX-R rackmount version.
**When more than three input boards are used for data acquisition or monitoring in the TMX-R rackmount system,
the maximum sample rate per channel will be one half the specified maximum sample rate for a specific input board.
Maximum bandwidth per channel is not impacted.
Specifications are subject to change. Registered trademarks belong to their respective companies.


购买提示  

高速数据采集系统

购买提示

1.阁下有任何产品问题请致电400-663-9117.
2.中仪将提供北京、上海、深圳、南京、重庆送货上门服务.
3.我们提供高速数据采集系统计量送检,在签收前请详细核查资料信息.
4.TY10高速数据采集系统价格根据配置和货期不同而不同,具体以合同为准.
5.我们为阁下提供保修TY10高速数据采集系统售后维修服务,提供后期技术支持.
6.阁下对TY10高速数据采集系统使用方法等有需求时,将为阁下找到高速数据采集系统说明书.
最近浏览

美国Astro-Med,Inc高速数据采集系统

代理商厂商品牌售后维修区域:北京-上海-浙江-广东-河南-杭州-郑州-广州-深圳-佛山-惠州-厦门-汕头-台湾-香港-天津-西安-宝鸡-杭州-温州-常州-无锡-苏州-南京-镇江-扬州-南通-合肥-徐州-常熟-石家庄-太原-呼和浩特-沈阳-长春-哈尔滨-南京-合肥-福州-南昌-济南-郑州-武汉-长沙-广州-南宁-海口-成都-贵阳-昆明-拉萨-西安-兰州-西宁-银川-乌鲁木齐-杭州-沈阳-长春-哈尔滨-济南-武汉-广州-南宁-成都-西安-大连-宁波-厦门-青岛-深圳-杭州-淮安-连云港-昆山-嘉兴-湖州-秦皇岛-邯郸-邢台-保定-张家口-承德-廊坊-呼和浩特-包头-鞍山-大庆-锦州-铁岭-盘锦-湛江-萧山-辽宁-淄博-宁夏-绵阳-云南-朝阳-陕西-青海-北海-唐山-吉林-苏州-昆山-无锡-镇江-常州-连云港-淮安-淮阴-盐城-扬州-徐州-宜兴-江阴-南通-扬州-上海-滁州-内蒙古-新疆有销售.北京亦庄开发区,天津滨海开发区,秦皇岛经济开发区,太原经济开发区,呼和浩特经济开发区,沈阳经济开发区,营口经济开发区,大连经济开发区,长春经济开发区,哈尔滨经济开发区,虹桥经济开发区,漕河泾开发区,连云港开发区,南通开发区,昆山开发区,南京开发区,杭州开发区,萧山开发区,温州开发区,宁波开发区,芜湖开发区,合肥开发区,福州开发区,福清融侨开发区,东山开发区,南昌开发区,威海开发区,烟台开发区,青岛开发区,郑州开发区,武汉开发区,长沙开发区,萝岗区开发区,广州南沙开发区,惠州大亚湾开发区,湛江开发区,南宁开发区,重庆开发区,成都开发区,贵阳开发区,昆明开发区,拉萨开发区,西安开发区,兰州开发区,西宁开发区,银川开发区,乌鲁木齐开发区,石河子开发区,金桥出口加工区,苏州工业园,宁波大榭开发区,厦门海沧投资区,海南洋浦开发区。

按字母分类: A| B| C| D| E| F| G| H| I| J| K| L| M| N| O| P| Q| R| S| T| U| V| W| X| Y| Z| 热门一| 热门二| 热门三| 热门四| 热门五|


中仪主页联系中仪了解中仪版权声明友情链接站点地图广告服务
CopyRight 2003年创立  版权所有  MRO工业品就是要仪器网
(5)
产品对比产品对比 隐藏对比框
对不起,您还没有选择产品
开始对比清 空