Models 555
Description
The Model 555 Series Differential Pressure Indicator offers a two sided
dial providing easier installation regardless of flow direction. It is used
on filters & strainers. The Rolling Diaphragm Sensing Element isolates
the high and low side of the indicator assuring filter efficiency (Reverse
pressure must be avoided).
Specifications:
Differential Pressure Range 0-5 PSID (0-0.35 bar) to 0-50 PSID (0-3.5 bar)
Accuracy ±5% F.S.
Dual Color Coded Dials (custom scales available)
Working Pressure 300 PSIG (20 bar)
Max. Operating Temp. +200º F (93ºC)
Body Material - Glass Filled Nylon (GFN)
Internal Materials - GFN, Ceramic, & Stainless Steel
Elastomers Buna-N (std.), Viton®* (opt.)
Direct Mounting SLOTTED INTERNAL HEX HEAD BOLT 3/8"-24 UNF 1.75" SPACING
1/4" FNPT Adapter (opt.)
Other Connection Options Available
Dimensions 2.27H" x 1.5W" x 2.88L"