Detector Uncompensated GM Tube Switch Functions • Audible Clicks On/Off • Off • Vibrate and Audible Alert • Audible Only Alert Operating Range Dose Rate: .1 - 15 R/hr Dose: .1 - 15 R/hr Accumulated Dose: .1 - 65 R Dose Rate Linearity Better than ±15% up to 15 R Energy Response Down to 30 KeV Gamma Sensitivity 1.5 cps/mR/hr referenced to Co-60 Audible Alarms 90db @ 1 ft. • accumulated dose • dose rate |
Alarm Thresholds Dose Alarm Default 500 mR Rate Alarm Default .5 R/hr Alarm and warning levels are user selectable with Optional Sentry Software. Connectors Headphone Connector, Internal Serial Header connector (cable comes w/ Optional Sentry Software). Power Requirements 9 Volt Battery. Typical battery life is 1500 hrs at background. Temperature Range -20° - + 50° C (-4° - +122° F) Weight 4.8 oz. with Battery (3.2 oz w/o battery) 8.3 oz w/ Xtreme Boot Size 3.8 x 2.4 x 1 in (96.5 x 70 x 25.4 mm) Includes Carrying Case |