gamma/neutron independent channels, with spectrum acquisition
- high sensitivity and fast response time
- visual, audio and vibration alarms
- wireless communication interface
- small, rugged, compact, user-friendly
- designed for ITRAP and ANSI standards
The PDS-100G and PDS-100GN are the new generation of gamma and gamma/neutron radiation
detectors. These sensitive pocket-sized devices are designed to detect, locate and quantify any radioactive materials as Special Nuclear Materials or as Radiological Dispersal Devices (RDD), in a very short time. The PDS-100G and GN feature the capability to transmit the measurement and the spectrum on request. They have been designed specially for First Responders, Law Enforcement, Customs inspectors and for Personnel and Site security in critical infrastructures.
Nuclear characteristics
detectors:
Gamma: CsI
Neutron: Li6
energy range (gamma): 35 keV to 1,8 MeV
energy range (neutrons): 0.025 eV to 10 MeV
gamma dose rate display: 0.01 µSv/h to 100µSv/h / 1 µR/h to 10mR/h
gamma count rate display: 0 to 99 999 cps
neutron count rate display: 0 to 999 cps
gamma alert response time: for a 0.5 µSv/h
increase (Am, Cs, Co) in 0.1 µSv/h
background: <1 sec.
neutron alert response time: mean time to