产品描述:
The system is suitable for monitoring the gas feedback equipment which is inserted into petrol pumps of filling stations. It checks whether the quantity of the gas recovered during refuelling is equal to the delivered fuel volume. The complete monitoring system consists of a controller Type 1098 and 1 or 2 gas sensors Type 8060. The sensors are connected to the intrinsically safe circuit of the controller. Petrol pulses and the fill nozzle signal are connected to the further
inputs . The controller assesses the gas and the petrol volume, then it compares the difference between these two volumes and indicates the current status and, if the need arises, a malfunction of the gas recovery system via a Businterface and digital outputs.If needed the controller supplies also the signalto switch off the petrol pump in compliancewith 21.BlmSchV.The Type 1094 hand-held terminal is necessaryfor use in maintaining the gas monitoring system.