NE7-240S 240升冷却保温箱
Product Name : NE7-240S Product Description : 240 Litre Cooled Incubator, Fan Assist Circulation New 2009 Nominal Tank Capacity : 240 Litre chamber Working capacity of the chamber can be smaller. Size selector : «Smaller Larger»240 Product Specification : This Clifton Cooled Incubator features precision time and temperature control with programming options from It can provide heating or cooling cycles or produce a controlled environment above or below ambient. Featuring forced air circulation with Fan speed regulation from 0 to 100%. Featuring wipe clean touch pad controls illuminated LCD display for viewing wide range of settings, programs, temperature and time values. The high grade 304 spec stainless steel chamber is sealed shut with a solid door. Other door options available include a window in the door or an internal glass door allowing the observation the chamber with no temperature disturbance. This model a 240 litre capacity Incubator supplied with 3 wire shelves, with the option for additional wire or perforated shelves up to maximum capacity of 10. The Cooled range can be specified with accessory "Photoperiodic System" lighting elements. This makes the Incubator suitable for plant growth, microorganisms, fungi, etc. A wide range of light sources, light colour and illumination intensity can be installed in the chamber. Temperature Range: Microprocessor control, dual pt100 temperature probes11 Auto diagnostic system. Digital LCD display to Sensitivity @ Uniformity @ Calibration Certificate @ Temperature and time programmable Temperature and time programmable in two ways: Six segment temperature-time profile with delay start13, heating up9, hold at set point12, each with timers from 1 minute to 99 hours. Continuous mode at set point with either delay start 13, or timed up to 999 hours12. Date and time setting, program can start unsupervised13. Audible alarm and display, setting Fast temperature rise to attain set point or normal with no overshoot9. Three program memory, re-called for use. Event log and program review temperature and time records. Average minimum and maximum temperature values recorded for each segment of the program for reference and validation. Manual Air-flap control, adjustable. Forced air circulation with Fan speed regulation from 10 to 100%. RS232 interface. Over-temperature protection Cass 1, thermal cut out Class 2, experiment/sample protection, adjustable setting above set point, heating switched off, audible and visual indication8. Accessory options Class 3, temperature protection, self resetting cut outs. Temperature sensor fail alarm11. Power failure control with auto resume. Interior and Case Using a 304 spec stainless steel interior for long working lfe and easy cleaning. Case construction stainless steel with powder painted exterior. With the solid door design there is the option of internal glass door or viewing window in outer door, these options are factory fit items. Incubators up to 115 litres are stackable. Internal Dimensions : 600w x 510d x 800h mm External Dimensions : 815w x 710d x 1420h mm Sensitivity/temperature stability @ ± Uniformity @ ± Temperature setting/control : Wipe clean controls/Keypad setting/Digital LCD display/Microprocessor control. Temperature display resolution : Fast realtime display of actual measured temperature in increments of ± Warranty Period : 3 Years Safety features : Control system diagnostic check on startup. Over-temperature protection Cass 1, thermal cut out Class 2, experiment/sample protection, adjustable setting above set point, heating switched off, audible and visual indication8. Accessory options Class 3, temperature protection, self resetting cut outs. Temperature sensor fail alarm11. Power failure control with auto resume. Safety Class : 1 + 2 fitted, options for 3+ Power consumption (W) @ 220-240V: 800W Voltage : 230V Packed Weight : Packed Dimensions : 100x88x Notes : · A range of ‘factory fit’ options are listed below as Accessories. · Before ordering please check the room or building access where this unit will be installed and electrical power requirements. · Sensitivity measurements based on temperature readings on shelf in centre of the chamber. · Uniformity measured in vertical axis in the chamber using Wired Shelves. · Working capacity of chamber can be smaller. · Temperature range can be extended to · With the solid door design there is the option of internal glass door to retain chamber temperature and allow viewing or a window can be specified in outer door · Do not place in direct sunlight and allow a · When no programs are active, the display shows current time and temperature inside chamber. When running a program the display shows program number, temperature inside chamber and status symbol showing the status of heating/cooling.