Accuracy: |
±5% of readingfor any reading above 20% of the Power Range selected for FM or CWsignals without AM. This accuracy is maintained for a full 37 dBdynamic rance with each 4410 Element (except No. 4410-1 200 kHz-535kHz which is accurate to ±10% of reading, 4410-15 1.0-1.8 GHz 4410-16 1.8-2.3 GHz wich are accurate to ±8% ofreading.) |
Ambient Temperature Range: |
Elements 4410-1through -8 -10 through -16 are temperature compensated forrated accuracy from 0° to 50° C (32° to 122°F) 4410-20 through-27 from 20° C to 30° C(68° to 86°F) |
Connector: |
QC Type (FemaleN normally supplied) |
Finish: |
Gray powdercoat |
FrequencyRange: |
200 kHz to 2.3GHz CW or FM |
Insertion VSWR: |
with NConnectors 1.25 max. to 2300 MHz |
Nominal Size: |
6 7/8" H x 51/8" W x 3 5/8" D, (175 mm x 130 mm x 92 mm) |
Over-Range Protection: |
To 120%ofnominal full scale (I.e. 12 W, 120 W, 1200 W, or 12,000 W). Nodamage or degradation to the unit will result, regardless of theRange Selector Switch position. |
PowerRange: |
2 mW to 10 W,20 mW to 100 W, 200 mW to 1 kW or 2 W to 10 kW full scale in onesingle Plug-in Element. Any Bird Series 4410-Element may beused. |
Weight: |
3lbs. (1.4kg) |
4410 SeriesElements | |||||||||
Table 9 - Full Scale Power Frequency Ranges 0-10, 30, 100, 300 Milliwatts, 1, 3, 10Watts | |||||||||
MHz |
30-50 |
50-88 |
88-108 |
- |
150-250 |
225-400 |
400-800 |
800-900 |
900-1000 |
Model |
4410-20 |
4410-21 |
4410-27 |
- |
4410-23 |
4410-24 |
4410-25 |
4410-26 |
4410-28 |