Pulse Rectifier Description
The Model 2015 Pulse Rectifier (Pulser) is an air-cooled DC power supply that is designed to work as any conventional rectifier with the added benefit of increased current distribution and reduced cathodic interference on adjacent buried structures. The major components consist of the pulse module, power transformer and control/monitoring panel.
Pulse Module: The pulse power module is the main component of the Pulser. The module consists of the power conversion circuitry that converts the AC to high voltage DC output pulses. It also contains the control, monitoring and communication circuitry. All solid-state power components are mounted on a massive aluminum heat sink. The main circuit board and associated components are also mounted to the heat sink and are protected by a steel housing. The output of the rectifier is electronically controlled to maintain a “constant current” during operation.
Main Power Transformer: The main power transformer is a single phase, toroidal isolation transformer. Toroidal transformers offer improved power efficiency, are lighter weight and are more compact than conventional laminated core power transformers.
Control/Monitoring Panel: This main panel controls and monitors the operational status of the system and contains the following components:
An output control dial (10-turn potentiometer) provides the means for adjusting the pulse output current.
A single, continuous reading ammeter displays system current output. Panel-mounted jacks are provided for cross checking meter accuracy.
The pulse train interrupt switch is available to interrupt the pulse output without switching off the main rectifier power.
Primary and secondary circuit breakers.
System status indicating lights.
Recessed potentiometers are included to adjust pulse width and frequency to improve performance on a site-specific basis.
Enclosures: A number of different enclosure types are available including an industry standard rectifier type cabinet as well as other commercially available decorative cabinets. With a compact physical dimension of 12” x 12” x 16”, the 2015 Pulser can even be located in existing, customer supplied cabinets. The standard rectifier type enclosure is manufactured from 11-gauge cold rolled steel with a thermally fused, multistage coating, white in color.
AC Input Section: The standard available AC input configuration is 115/230 volt, single phase. Customer specified AC inputs are also available as a special order.
Removable Safety Panel: This removable panel shields the high voltage pulse output lugs, the AC secondary interconnect, and access to interrupter connection lugs. These lugs allow for the use of a portable interrupter. It is important to note that a portable interrupter only interrupts a low voltage, low current signal rather than the pulse output. This allows the use of virtually all types of commercially available, portable current interrupters.
Serviceability Features
On the standard rectifier type enclosure, front and side opening doors are provided for easy installation and servicing.
   The entire rectifier assembly is built on a slide-out chassis allowing easy removal from the cabinet for service.
   The major electronic components are enclosed in a single module housing.
   A pulse interrupt circuit is provided which will function with any portable current interrupter.
  
Temperature monitoring devices are built into the system. These devices monitor critical electronic component operating temperatures. If the operating temperature should exceed a maximum range, the pulse module output will be interrupted until the temperature reduces to a safe operating level. At that time, the system will automatically restart and return to previous operating parameters.
   For structures that require in excess of 15 amps of protective current, additional rectifiers can be added to the same structure and operated in parallel to provide the required current.
   For multiple structures at a common location, additional rectifiers may be installed on a common anode ground bed. Each rectifier will provide an independently controlled, constant current to each structure.
Model 2015 "Pulser" pulse module
Theory of Operation
The Pulser produces very short duration, very high voltage, direct current electrical pulses for cathodically protecting buried metallic structures, such as pipelines and well casings, from external corrosion.
Pipelines, well casings, and other steel structures buried in soil, corrode. Cathodic Protection has been used to mitigate corrosion for many years. Sufficient direct electrical current (DC) is caused to flow from the soil to the surface of the structure. Typically, the negative lead from a DC rectifier is connected to the structure to be protected, and the positive lead to an anode bed. The ground bed usually consists of one or more rods, called anodes, fabricated from expendable materials such as graphite or silicon steel. The anodes are buried in deep wells, or shallow holes or trenches, in the vicinity of the structure to be protected. The process is called Cathodic Protection, because protective cathodic reactions are caused to take place on the surface of the structure being protected.
The DC current mitigates corrosion by electrochemically reducing any corrosive oxygen molecules and hydrogen ions that may be adsorbed on the surface of the structure in contact with the soil. As additional molecules and ions diffuse from the soil and become adsorbed onto the steel surface, they are also reduced by the continuously flowing direct current. There are certain drawbacks to conventional cathodic protection, however. Current flows in the ground continuously in a relatively large three-dimensional envelope. If there are other foreign metallic structures buried in the soil within the current envelope, damage in terms of metal loss will very likely occur to the foreign structures. Also, the "throw", or distance down the pipeline or well casing, that can be protected, is limited by the magnitude of the current reaching the more distant corroding surfaces.
The corrosive oxygen molecules and hydrogen ions, adsorbed on the surface of the buried structure, are electrochemically reduced within microseconds after the application of cathodic current. Before the corrosion reactions can begin again, additional molecules and ions must diffuse to the surface of the structure from the surrounding soil and become adsorbed. The destructive diffusion and adsorption processes are orders of magnitude slower than the protective reduction process, particularly when the ions are not being driven by a continuously applied cathodic protection voltage.
With Pulse Cathodic Protection the corrosive molecules and ions are electrochemically reduced with very short duration but very high current pulses. Since throw is a function of current magnitude, the very high pulsed currents result in greatly improved throw down the length of the structure. Because of the natural electrical characteristics of the structure/anode system, the greatly improved high current throw is further enhanced by the inductive and capacitive redistribution of that current.
Also, the very short duration pulses are separated by relatively long "off" intervals. The pulse voltage is applied for less than 20% of the total time. Thus, the continuous current envelope and the resulting interference on foreign structures is greatly reduced.
 
购买提示  

阴极保护脉冲整流器

购买提示

1.阁下有任何产品问题请致电400-663-9117.
2.中仪将提供北京、上海、深圳、南京、重庆送货上门服务.
3.我们提供阴极保护脉冲整流器计量送检,在签收前请详细核查资料信息.
4.TY10阴极保护脉冲整流器价格根据配置和货期不同而不同,具体以合同为准.
5.我们为阁下提供保修TY10阴极保护脉冲整流器售后维修服务,提供后期技术支持.
6.阁下对TY10阴极保护脉冲整流器使用方法等有需求时,将为阁下找到阴极保护脉冲整流器说明书.
最近浏览

英国密析尔MICHELL阴极保护脉冲整流器

代理商厂商品牌售后维修区域:北京-上海-浙江-广东-河南-杭州-郑州-广州-深圳-佛山-惠州-厦门-汕头-台湾-香港-天津-西安-宝鸡-杭州-温州-常州-无锡-苏州-南京-镇江-扬州-南通-合肥-徐州-常熟-石家庄-太原-呼和浩特-沈阳-长春-哈尔滨-南京-合肥-福州-南昌-济南-郑州-武汉-长沙-广州-南宁-海口-成都-贵阳-昆明-拉萨-西安-兰州-西宁-银川-乌鲁木齐-杭州-沈阳-长春-哈尔滨-济南-武汉-广州-南宁-成都-西安-大连-宁波-厦门-青岛-深圳-杭州-淮安-连云港-昆山-嘉兴-湖州-秦皇岛-邯郸-邢台-保定-张家口-承德-廊坊-呼和浩特-包头-鞍山-大庆-锦州-铁岭-盘锦-湛江-萧山-辽宁-淄博-宁夏-绵阳-云南-朝阳-陕西-青海-北海-唐山-吉林-苏州-昆山-无锡-镇江-常州-连云港-淮安-淮阴-盐城-扬州-徐州-宜兴-江阴-南通-扬州-上海-滁州-内蒙古-新疆有销售.北京亦庄开发区,天津滨海开发区,秦皇岛经济开发区,太原经济开发区,呼和浩特经济开发区,沈阳经济开发区,营口经济开发区,大连经济开发区,长春经济开发区,哈尔滨经济开发区,虹桥经济开发区,漕河泾开发区,连云港开发区,南通开发区,昆山开发区,南京开发区,杭州开发区,萧山开发区,温州开发区,宁波开发区,芜湖开发区,合肥开发区,福州开发区,福清融侨开发区,东山开发区,南昌开发区,威海开发区,烟台开发区,青岛开发区,郑州开发区,武汉开发区,长沙开发区,萝岗区开发区,广州南沙开发区,惠州大亚湾开发区,湛江开发区,南宁开发区,重庆开发区,成都开发区,贵阳开发区,昆明开发区,拉萨开发区,西安开发区,兰州开发区,西宁开发区,银川开发区,乌鲁木齐开发区,石河子开发区,金桥出口加工区,苏州工业园,宁波大榭开发区,厦门海沧投资区,海南洋浦开发区。

按字母分类: A| B| C| D| E| F| G| H| I| J| K| L| M| N| O| P| Q| R| S| T| U| V| W| X| Y| Z| 热门一| 热门二| 热门三| 热门四| 热门五|


中仪主页联系中仪了解中仪版权声明友情链接站点地图广告服务
CopyRight 2003年创立  版权所有  MRO工业品就是要仪器网
(5)
产品对比产品对比 隐藏对比框
对不起,您还没有选择产品
开始对比清 空