Technical Specifications | |
VDC |
20 mV - 1000 V(6 cal.) |
Basic accuracy |
±(0,06% + 10d) |
VAC |
20 mV - 750 V(6 cal.) |
Basic accuracy |
±(0,7% + 50d) |
Bandwidth |
40 - 100 kHz |
IDC |
20 mA, 200 mA, 2A, 10A |
Basic accuracy |
±(0,2% + 40d) |
IAC |
20 mA, 200 mA, 2A, 10A |
Basic accuracy |
±(0,8% + 50d) |
Bandwidth |
40 - 3000 Hz |
Resistance |
200 ohms - 2000 Mohms (8 cal.) |
Basic accuracy |
±(0,3% + 30d) |
Capacity |
4nF à 40 mF (8 cal.) |
Basic accuracy |
±(0,9% + 5d) |
Frequency |
20 Hz - 1 MHz (6 cal.) |
Basic accuracy |
±(0,01% + 10d) |
Temperature |
-100°C to +1200°C |
Basic accuracy |
±(0,1% + 3°C) |
Continuité |
with buzzer, 50 ohms |
Diode test |
3,3 V |
current |
< 1,1 mA |
Special Functions | |
Zoom & central zero (bargraph) |
yes |
Auto HOLD |
yes |
Fuse detection |
yes |
Indicator of test lead connection |
yes |
MAX/MIN/AVG & MAX-MIN |
yes |
Relatif mode |
yes |
dB et dBm |
yes |
Limits test |
yes |
Memoiry |
1000 values |
Datalogger function |
6000 values |
Peak Hold |
0,5ms |
RS-232 Interface (isolated) |
yes |
Software + cable |
acquisition software (SI689), RS-232 cable (SI659) |
General Specifications | |
Display |
20 000 points |
LCD backlit |
oui |
Bargraph |
83 segments |
Measurement rate |
2 /sec. |
Power supply |
9V (type 6F22) |
Battery life |
100 h. |
Auto power off |
yes, 30mn |
IEC 61010 |
CAT. III 600 V CAT. II 1000V |
Dimensions (mm) |
212 x 100 x 55 |
Weight |
600 g |
Protection level |
IP 64 |
Warranty |
3 years |