Specifications |
Model 2706A |
DC Volts |
|
Ranges |
200mV, 2V, 20V, 200V, 1000V |
Resolution |
100uV, 1mV, 10mV, 100mV, 1V |
Accuracy |
+-(0.5% + 1 Digit) |
Overload Protection |
200 mV Range 500V DC + AC Peak, 350V RMS Sine: All Other Ranges: 1200V DC + AC Peak, 800V RMS, Sine |
Input Impedance |
10 MΩ |
AC Volts |
|
Ranges |
200 mV, 2V, 20V, 200V, 750V |
Resolution |
100 uV, 1 mV, 10 mV, 100 mV, 1V |
Basic Accuracy |
+-(1.5% + 4 Digits) |
Frequency Response |
50 to 500 Hz |
Overload Protection |
200 mV Range: 500 VDC + AC Peak, 350V RMS, Sine: All Other Ranges: 1200 V DC + AC Peak, 800V RMS, Sine: |
Input Impedance |
10 MΩ |
DC Current |
|
Ranges |
200uA, 2mA, 20mA, 200mA, 2A, 10A, (2a: 2706A only) |
Resolution |
0.1uA, 1uA, 10 uA, 100 uA, 1 mA, 10 mA (1 mA: 2706A only) |
Accuracy |
+-(1% + 1 Digit): 10A Range: +-(2% + 3 Digits) |
Burden Voltage |
10A and 200mA range: 750mV max.; All Other Ranges: 325mV max. |
Overload Protection |
10A Range: Unfused: All Other Ranges: 250V Fuse |
AC Current |
|
Ranges |
200uA, 2mA, 20mA, 200mA, 2A, 10A (2A: 2706A only) |
Resolution |
0.1uA, 1uA, 10uA, 100uA, 1mA, 10mA, (1 mA: 2706A only) |
Accuracy |
+-(1.2% + 4 digits): 10A Range: +-(2% + 4 Digits) |
Frequency Response |
50 to 500 Hz |
Burden Voltage |
10A and 200mA Range: 750mV max.: All Other Ranges: 325mV max. |
Overload Protection |
10A Range: Unfused; All Other Ranges: 250V Fuse |
Resistance |
|
Ranges |
200Ω, 2kOhm, 20kOhm, 200kOhm, 2MOhm, 20MOhm, 200MOhm (200MOhm: 2707A only) |
Resolution |
0.1Ω, 1Ohm, 10Ohm, 100Ohm, 1 kOhm, 10 kOhm, 100 kOhm (100kOhm: 2707A only) |
Basic Accuracy |
200 MΩ Range (2707A only): +-(5% + 10 Dgt.); +-(0.8% + 1 Digit) |
|
20 MΩ Range: +-(3% + 1 Digit) |
Overload Protection |
500 VDC + AC Peak |
Diode Test |
Tested at 1.6mA and 3.2V Max. |
Transistor Test (hFE) |
Base Current: 10 uA Vce; 2.8V; Gain Indication: 0 to 1,000 |
Capacitance |
|
Ranges |
2,000 pF, 20 nF, 200 nF, 2 uF, 20 uF |
Resolution |
1 pF, 10 pF, 100 pF, 1 nF, 10 nF |
Accuracy |
+-(3% + 10 Digits) |
Test Frequency, Voltage |
400 Hz, 50 mV |
Frequency |
|
Ranges |
2 kHz, 20 kHz, 200 kHz, 2 MHz, 15 MHz |
Resolution |
1 Hz, 10 Hz, 100 Hz, 1kHz, 10kHz |
Accuracy |
+-(0.1% + 2 Digit) |
Sensitivity |
1Vrms |
Overload Protection |
500V DC + AC Peak |
Logic Probe (TTL) |
|
Logic Threshold |
Does not apply |
Minimum Pulse Width |
|
Input Impedance |
|
Overload Protection |
|
Temperature |
|
Range |
-4 0 to 1400 0 F (-20 0 to + 750 0 C) |
Accuracy |
|
-4 0 to + 900 0 F (-20 0 to 500 0 C) |
+-(2% + 4 0 F) +-(2% + 2 0 C) |
900 0 to + 1400 0 F (500 0 to + 750 0 C) |
+-(3% + 4 0 F) +-(3% + 2 0 C) |
Continuity Tone |
Tone Sounds within 100 mS for Resistance Under 100V |
General |
|
Display |
3 1/2 digit, high-contrast 0.7 LCD, 1999 counts |
Sampling |
3 times/sec. (nominal) |
Operating Temp: |
32 0 to 104 0 F (0 0 to + 40 0 C), 0 to 70% RH |
Storage Temp |
-4 0 to 140 0 F (-20 0 to 60 0 C), 0 to 80% RH |
Power Requirements |
9V NEDA 1604. |
Battery Life |
200 hours (alkaline) nominal 275 hours (alkaline) Nominal (2703B only) |
Dimensions (HxWxD) |
5.9x3.1x1.3 (150x79x33 mm) |
One Year Warranty | |
Accessories | |
SUPPLIED: Battery, Test Leads, Instruction Manual, Thermocouple Probe (2706A only) OPTIONAL: TL-2A Deluxe Test Leads, TL-3 Accessory Tip Kit (for TL-2A), PR-28A High Voltage DMM Probe (40kVDC), TL-130A General Purpose DMM Kit Carrying Case (not included): LC-29B |