These highly corrosion resistant flow meters are suitable foroth liquid and gaseous applications.
The SM-6-V combines a flow meter with a precision needle valve to regulate and adjust the flow.
In applications where flow monitoring is critical, the flowmeter can be equipped with a bi-stable flow sensor. Anydeviation from the set point results in an alarm signal
Technical Data: Flow Meter Ambient temperature 80 °C
Media temperature max. 150°C
(with part no. 405610 max. 80°C)
Operating pressure max. 4 barHead PTFE
Seal PTFEAdjusting screw PVDF / Viton or
PCTFE / Perfluorelastomer
Metering tube Borosilicate glass
Float Hastelloy C 4 or
optional PEEK with iron core
Union nut PPS fiberglass reinforced