MODEL NUMBER |
APS-1102 |
|
|
MAXIMUM OUTPUT CAPACITY |
|
|
|
AC |
INPUT(100~180V) |
750VA |
|
|
INPUT(180~250V) |
1000VA |
|
DC |
INPUT(100~180V) |
750W |
|
|
INPUT(180~250V) |
1000W |
|
OUTPUT VOLTAGE |
|
|
|
AC |
100V |
0.0V~135.0V |
|
|
200V |
0.0V~270.0V |
|
DC |
100V |
-190.0V~+190.0V |
|
|
200V |
-380.0V~+380.0V |
|
OUTPUT MAX. CURRENT |
|
|
|
AC |
100V |
10A |
|
|
200V |
5A |
|
DC |
100V |
10A |
|
|
200V |
5A |
|
OUTPUT MAXIMUM PEAK CURRENTS |
|
|
|
|
100V |
40Apk |
|
|
200V |
20Apk |
|
FREQUENCY |
|
|
|
|
SETTING RANGE |
1.0Hz~550.0Hz |
|
|
SETTING ACCURACY |
±100ppm |
|
WAVEFORM |
|
|
|
|
SINE WAVE ,SQUARE WAVE, ARBITRARY WAVE (UP TO 16 TYPES CAN BE SAVED) |
|
|
|
OUTPUT DISTORTION RATE |
0.5% MAX(50HZ/60HZ) |
|
LINE VOLTAGE REGULATION |
|
|
|
|
POWER INPUT VOLTAGE |
100V/120V/230V, no load ,rated output |
|
LOAD VOLTAGE REGULATION RATE |
|
|
|
|
|
0.5% MAXIMIM (At output terminal under no load rated resistance load) |
|
MEASUREMENT |
|
|
|
|
RANGE |
RESOLUTION |
ACCURACY |
FREQUENCY COUNTER |
1.0 ~550.0 Hz |
0.1Hz |
±100ppm(1.0 Hz to 550.0Hz) |
RMS Volt-Meter(AC+DC) |
Full Scale 100V:225.0Vrms |
0.1Vrms |
±0.5% of the full scale |
|
Full Scale 200V:450.0Vrms |
0.1Vrms |
±0.5% of the full scale |
RMS Amp-Meter(AC+DC) |
Full Scale 15.00A |
0.01Arms |
±1.0% of the full scale |
Wattage Meter |
Full Scale 1200W |
1W |
±2% of the full scale |
Load Power Factor Measurement |
0.00 ~ 1.00 |
0.01 |
|
Load Crest Factor Measurement |
0.00 ~ 50.00 |
0.01 |
|
External Synonization Frequency Measurement |
38.0~525.0Hz |
0.1HZ |
±0.2Hz |
Phase when output is on |
0.0°~359.9° |
0.1° |
|
External signal Input |
|
|
|
Gain setting range |
100V range 0.0~200.0 times |
0.1 |
±5% |
|
200V range 0.0~400.0 times |
0.1 |
±5% |
|
|
|
|
OUTPUT MODE |
|
|
|
|
|
|
|
ACINT Mode |
V |
|
|
AC-EXT Mode |
V |
|
|
AC-ADD Mode |
V |
|
|
AC-SYNC Mode |
V |
|
|
AC+DC-INT Mode |
V |
|
|
AC+DC-EXT Mode |
V |
|
|
AC+DC-ADD Mode |
V |
|
< |